DESIGN AND EVALUATION OF A HEAT PUMP DRYING SYSTEM USING REPURPOSED AIR CONDITIONING COMPONENTS

Các tác giả

  • Huynh Thi Tuong Vy Ho Chi Minh City University of Technology, Vietnam National University, Ho Chi Minh City Tác giả
  • Bui Ngoc Pha Ho Chi Minh City University of Technology, Vietnam National University, Ho Chi Minh City Tác giả liên hệ

DOI:

https://doi.org/10.62985/j.huit_ojs.vol26.no3E.663

Từ khóa:

Heat pump drying (HPD), drying system design, refrigeration unit reuse, sub-condenser.

Tóm tắt

Heat pump drying presents an environmentally friendly alternative to traditional drying methods. As discarded air conditioners and refrigerators increasingly contribute to electronic waste, this research explores the potential of repurposing components from old air conditioning systems to construct a heat pump drying system. The study involved three no-load trial sets. Key findings emphasize the importance of releasing excess heat to the environment via a sub-condenser for maintaining system stability and operational safety, as observed in Trial 3.1. Additionally, in Trial 3.2, without an electric heater, the inlet drying airflow temperature ranged only from 37 °C to 44 °C. Following this, in Trial 3.3, with the heater at 50% capacity, the temperature reached 50 °C to 56 °C. Overall, this research highlights the feasibility of repurposing air conditioning systems to develop efficient and cost-effective heat pump drying systems. 

Tài liệu tham khảo

[1] F. Icier, N. Colak, Z. Erbay, E. H. Kuzgunkaya, and A. Hepbasli, “A comparative study on exergetic performance assessment for drying of broccoli florets in three different drying systems,” Drying Technology, vol. 28, no. 2, pp. 193–204, 2010, doi: https://doi.org/10.1080/07373930903524017

[2] K. J. Chua, S. K. Chou, and W. M. Yang, “Advances in heat pump systems: A review,” Applied Energy, vol. 87, no. 12, pp. 3611–3624, Dec. 2010, doi: https://doi.org/10.1016/j.apenergy.2010.06.014

[3] M. Song, S. Deng, N. Mao, and X. Ye, “An experimental study on defrosting performance for an air source heat pump unit with a horizontally installed multi-circuit outdoor coil,” Applied Energy, vol. 165, pp. 371–382, 2016, doi: https://doi.org/10.1016/j.apenergy.2015.12.107

[4] T. Kivevele and Z. Huan, “A review on opportunities for the development of heat pump drying systems in South Africa,” South African Journal of Science, vol. 110, no. 5/6, 2014, doi: https://doi.org/10.1590/sajs.2014/20130236

[5] O. Alves-Filho, Heat Pump Dryers: Theory, Design and Industrial Applications, 1st ed. Boca Raton, FL, USA: CRC Press, 2015, pp. 1–3, 6–25.

[6] F. Wang, C.-H. Liang, M.-T. Yang, and X.-S. Zhang, “Preliminary study of a novel defrosting method for air source heat pumps based on superhydrophobic fin,” Applied Thermal Engineering, vol. 90, pp. 136–144, Nov. 2015, doi: https://doi.org/10.1016/j.applthermaleng.2015.07.003

[7] K. J. Chua, S. K. Chou, J. C. Ho, and M. N. A. Hawlader, “Heat pump drying: Recent developments and future trends,” Drying Technology, vol. 20, no. 8, pp. 1579–1610, 2002, doi: https://doi.org/10.1081/DRT-120014053

[8] K. K. Patel and A. Kar, “Heat pump assisted drying of agricultural produce-an overview,” Journal of Food Science and Technology, vol. 49, pp. 142–160, 2012, doi: https://doi.org/10.1007/s13197-011-0334-z

[9] V. Rao Pendyala, S. Devotta, and V. S. Patwardhan, “The economics of heat pump assisted drying systems,” Journal of Heat Recovery Systems, vol. 6, no. 6, pp. 433–442, 1986, doi: https://doi.org/10.1016/0198-7593(86)90035-4

[10] TechSci Research, Vietnam Air Conditioner Market by Type, by End User, by Region, Competition, Forecast and Opportunities, 2020–2030F. TechSci Research, 2025.

[11] T. T. Huynh, V. H. Ha, and D. Q. Nguyen, “An overview of electronic waste recycling in Vietnam,” Journal of Material Cycles and Waste Management, vol. 19, pp. 536–544, 2017, doi: https://doi.org/10.1007/s10163-015-0448-x

[12] D.-Q. Nguyen, E. Yamasue, H. Okumura, and K. N. Ishihara, “Use and disposal of large home electronic appliances in Vietnam,” Journal of Material Cycles and Waste Management, vol. 11, pp. 358–366, 2009, doi: https://doi.org/10.1007/s10163-009-0264-2

[13] URENCO Urban Environmental Company Limited, Report on the Development of E-waste Inventory in Vietnam. URENCO Urban Environmental Company Limited, 2007.

[14] T. Kudra and A. S. Mujumdar, Advanced Drying Technologies, 2nd ed. Boca Raton, FL, USA: CRC Press, 2009, pp. 263–272.

[15] İ. Dinçer and M. Kanoğlu, Refrigeration Systems and Applications, 2nd ed. West Sussex, U.K.: Wiley, 2010, pp. 155–169.

[16] Y. A. Çengel and M. A. Boles, Thermodynamics: An Engineering Approach, 8th ed. New York, NY, USA: McGraw-Hill Education, 2015, pp. 283–287.